版权所有©北京全波仪器京ICP备12039067号

N5230C

Agilent N5230C PNA-L Microwave Network Analyzer Model:N5230C-525 Frequency Range:10MHz~50GHz opt:525,10 MHz to 50 GHz, 2 port, configuable test set and extended power range; 551,N-port calibrated measurements; 010,Time Domain; Stock:1

  Key Features & Specifications
  300 kHz to 6/13.5/20 GHz and 10 MHz to 20/40/50 GHz
  2- or 4- ports with two built-in sources
  110 dB system and 122 dB receiver dynamic range, 32,001 points, 32 channels
  < .006 dB rms (Option 22x)
  Measurement speed: 4 to 9 ?s per point
  Description
  The PNA-L is designed for your general-purpose network analysis needs and priced for your budget.
  300 kHz to 6 GHz, 2-port
  300 kHz to 13.5 GHz, available in 2- and 4-port
  10 MHz to 20 GHz, available in 2- and 4-port
  10 MHz to 40 GHz, 2-port
  10 MHz to 50 GHz, 2-port
  Intuitive operation simplifies and speeds measurements
  The PNA-L offers a 8.4 inch touch screen, simple interface with pull down menus, hard and soft keys, and online help.
  Option:
  N5230C-010——Time  domain;
  N5230C-020——300 kHz to 6 GHz, 2 port, standard test set;
  N5230C-025——300 kHz to 6 GHz, 2 port, configurable test set and extended power range;
  N5230C-080——Frequency offset mode;
  N5230C-082——Scalar calibrated converter measurements;
  N5230C-120 —— 300 kHz to 13.5 GHz, 2 port, standard test set;
  N5230C-125 —— 300 kHz to 13.5 GHz, 2 port, configurable test set and extended power range;
  N5230C-140 —— 300 KHz to 13.5 GHz, 4 port, standard test set;
  N5230C-145 ——300 KHz to 13.5 GHz, 4 port, configurable test set and extended power range;
  N5230C-146 ——300 KHz to 13.5 GHz, 4 port, configurable test set, extended power range, and internal second source;
  N5230C-1A7 ——ISO 17025 compliant calibration;
  N5230C-1CM ——Rackmount kit for installation without handles;
  N5230C-1CP ——Rackmount kit for installation with handles;
  N5230C-220 ——10 MHz to 20 GHz, 2 port, standard test set;
  N5230C-225 ——10 MHz to 20 GHz, 2 port, configurable test set and extended power range;
  N5230C-240 ——300 kHz to 20 GHz, 4 port, standard test set;
  N5230C-245 ——300 kHz to 20 GHz, 4 port, configurable test set and extended power range;
  N5230C-246 ——300 KHz to 20 GHz, 4 port, configurable test set, extended power range, and internal second source;
  N5230C-301 ——Application for use with standard CalPods;
  N5230C-302 ——Application for use with temperature-characterized CalPods;
  N5230C-420 ——10 MHz to 40 GHz, 2 port, standard test set;
  N5230C-425 ——10 MHz to 40 GHz, 2 port, configurable test set and extended power range;
  N5230C-520 ——10 MHz to 50 GHz, 2 port, standard test set;
  N5230C-525 ——10 MHz to 50 GHz, 2 port, configuable test set and extended power range;
  N5230C-550 ——Add 4-port measurement application;
  N5230C-551 ——N-port calibrated measurements;
  N5230C-897 ——Built-in performance test software for Agilent inclusive calibration, perpetual license;
  N5230C-898 ——Built-in performance test software for standards compliant calibration, perpetual license;
  N5230C-A6J ——ANSI Z540 compliant calibration;
  N5230C-UK6 ——Commercial Calibration Certificate with test data;